WPC-200 (Polyurethane Waterproofing Coating)

CCI WPC-200 is a reactive moisture-curing film forming polymer waterproofing coating. It is made of isocyanate and polyether as raw materials.

It is mixed with various additives such as latent curing agents and plasticizers. It is made through high-temperature dehydration and polymerization using a special process.

When used, it is coated on the waterproof base layer, and the -NCO end group in the polyurethane polymer reacts chemically with the moisture in the air to form a tough, soft, and seamless rubber waterproof membrane on the surface of the base layer.

INQUIRE / GET QUOTE

Product Features:
    • Ready to use on site, easy to construct. There are no strict requirements on the moisture content on the base layer. It can be constructed on a relatively humid base surface or under conditions of high relative humidity.
 
    • Polyurethane coating film has high tensile strength, high elongation, good elasticity, and good high and low temperature resistance. Strong adaptability to base layer shrinkage and cracking deformation.
 
    • One application can reach a thickness of 1-3mm, and the coating film is dense, without pinholes or bubbles.
 
    • Strong adhesion, no need to apply base treatment agent on various base layers that meet the requirement.
 
    • The color is adjustable and can meet the requirements of different customers for different surface colors.
  Scope of Application:
    • It is suitable for waterproofing construction of various civil and industrial buildings such as floors, basements, toilets and bathrooms, and swimming pools. It is more suitable for waterproofing projects with complex shapes and vertical and horizontal pipes.
  Construction:
    • The base layer must be strong, flat, and free of debris. The inner and outer corners must be arc-shaped. The diameter of the inner corner must be greater than 50mm, and the diameter of the outer corner must be greater than 50mm.
 
    • Ingredients and Dosage: Stir evenly according to the construction dosage. The reference dosage for 1mm thick coating is about 1.3-1.5kg/m2.
 
    • Large-area waterproofing construction: Apply the mixed paint evenly with a rubber or plastic scraper. The thickness should be consistent, generally 1.5mm-2mm. It should be applied 3-4 times. The subsequent application should be applied before the previous application. After curing and forming a film, it is painted in a vertical direction, usually as a separate film, and an additional layer of matrix reinforcement material should be laid on the underground engineering floor.
 
    • Coating Film Thickness: 1.2-2.0mm for underground projects, generally 1.5mm. Toilet and bathroom should not be less than 1.5mm. When multiple layers of waterproofing are used for exposed roof projects, the thickness of each layer should not be less than 1.2mm, and the waterproof grade is III. When the roof is fortified, the waterproof thickness shall not be less than 2mm. When the carcass reinforcement material is added between the coatings, the thickness of the coating below the carcass shall not be less than 1.0mm, and the thickness of the upper coating shall not be less than 0.5mm.
 
    • Construction of facing layer: Sprinkle clean sand on the surface before the last coat of paint is solidified.
 

Technical Parameters:

# Parameters Result
Type I Type II Type III
1 Solid content, % ≥85
2 Drying Time Surface Drying Time, h ≤12
Working Time, h ≤24
3 Tensile Strength, MPa ≥2.0 ≥6.0 ≥12.0
4 Elongation at break, % ≥500 ≥450 ≥150
5 Impermeable 0.3MPa @ 30 mins Impermeable
6 Low Temperature Bendability, ˚C ≤-35
7 Bonding Strength, MPa ≥1.0
8 Leveling Obvious marks after 20 minutes
Note: This performance is not applicable to single-component and spray-coated products

Storage and Transportation:

    • Store materials in a dry place with ventilated room.

 

    • During transportation, strictly protect against sunlight and rain, prevent collisions, and pay attention to fire prevention.

 

    • Product storage period is half a year, and it must be re-inspected after the storage period. It can be used later.

 

Packaging:

-25 kgs/pail

SEE WHAT OUR SATISFIED CUSTOMERS SAYS

John Smith
John SmithProject Manager
"We've been using CCI Chemical's concrete admixtures and waterproofing solutions for several years on our commercial construction projects. The difference in quality is undeniable. Their products consistently deliver superior strength and durability, while the waterproofing membranes provide unmatched protection. Plus, their reliable delivery ensures we stay on schedule. CCI Chemicals is a trusted partner and a key contributor to our success."
Billy Wilsons
Billy Wilsons Project Lead
"When we were faced with a complex waterproofing challenge on our high-rise development, CCI Chemicals stepped in with their expertise. Their team promptly assessed the situation and recommended a customized solution using their advanced sealants. The results were impressive, and thanks to their efficient products, we were able to complete the project on time and under budget. CCI Chemicals knowledge and innovative solutions saved us time and money."
David Lee
David LeeCEO
"As a company committed to sustainable building practices, we were looking for construction chemicals that offered exceptional performance without harming the environment. CCI Chemicals exceeded our expectations with their eco-friendly product line. Their concrete admixtures deliver the strength and workability we need, while minimizing our environmental impact. Beyond the products, their customer service is outstanding. The team is always responsive and helpful, making them a pleasure to work with."
SATISFIED CUSTOMERS
0
INDUSTRY SERVED
0
COUNTRIES
0

WE ARE LOCATED AT

SIGN UP FOR OUR NEWSLETTER TO GET WEEKLY UPDATES ON EXCLUSIVE OFFERS AND DISCOUNTS!

+63 917 579 0055

QUICK LINKS
ABOUT
SERVICES
PRODUCTS
TEAM
CONTACT US
QUICK LINKS APPOINTMENTS
BLOG/NEWS
FAQ
TEAM
INQUIRY

909 HIGH STREET SOUTH CORPORATE PLAZA TOWER 1, BGC TAGUIG PHILIPPINES

COPYRIGHT 2024 CYANCLAY | PRIVACY POLICY | TERMS OF USE